:QUEStionable:PTR
:STATus:QUEStionable:PTR
This command sets the positive transition filter of the questionable status event register.
:QUEStionable:NTR
:STATus:QUEStionable:NTR
This command sets the negative transition filter of the questionable status event register.
:SYSTem Subsystem
(default)
:ERRor?
:SYSTem:ERRor[:NEXT]?
Return Parameters: Integer error number
Query command is a request for the next entry in the instrument’s error queue. Error messages in the
queue contain an integer in the range [–32768, 32768] denoting an error code and associated
descriptive text.
:PRESet
:SYSTem:PRESet
Resets most instrument functions to factory- defined conditions. This command is similar to the *RST
command.
:VERSion?
:SYSTem:VERSion?
Returns the SCPI version number that the instrument software complies with [1999.0]
[:SYSTem:COMMunicate] Subsystem
:SYSTem:COMMunicate:LAN:CONFig
:SYSTem:COMMunicate:LAN:DEFaults
:SYSTem:COMMunicate:LAN:DHCP:TIMeout
:SYSTem:COMMunicate:LAN:DOMain